C&K systems ST800L+ Manuale di Installazione Pagina 8

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 16
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 7
7
To enter engineering mode, enter the engineering code and then press the #
(HASH) key. This forces the panel into engineering mode Note: If left
unattended for approximately 60 seconds it will revert to day mode.
To exit engineering mode, confirm any options you have selected with the *
(STAR) key, then close ALL tamper circuits and wait for approximately 60
seconds after which the panel will automatically exit engineering mode or
pressing the # (HASH) key will manually exit engineering.
If you need to stay in engineering for longer unattended periods, once in
engineering mode open a tamper circuit. The easiest way to do this is to
remove the lid of the panel or keypad.
PROGRAMMING
To exit all options press * to confirm the selection The accept tone will
sound.
CHIME 2 1 (Range - any alarm zone)
Enter 2-1. Enter the keys corresponding to the zone(s) required to chime. On
exit from engineer mode zones selected will be set to chime, the customer may
disable chime only on zones programmed with this option (see user manual).
If no zones are selected the user will not be able to access their chime option
and an error tone will be heard.
SOUND OPTIONS 2 2
Enter 1 Disable exit / entry sounds in part and home set
Enter 2 Disable accept / error sounds in part and home set
EXIT TIME 3 0 (Range 10-90 Seconds.)
Enter 3-0. A new time can be programmed by entering a key from the table.
Enter 1 10 Seconds. Led 1 on.
Enter 2 15 Seconds. Led 2 on.
Enter 3 30 Seconds. Led 3 on. (Factory default)
Enter 4 45 Seconds. Led 4 on.
Enter 5 60 Seconds. Led 5 on.
Enter 6 90 Seconds. Led 6 on.
ENTRY TIME 3-1 (Range 10-90 seconds)
Enter 3-1. A new time can be programmed by entering a key from the table.
Enter 1 10 Seconds. Led 1 on.
Enter 2 15 Seconds. Led 2 on.
Enter 3 30 Seconds. Led 3 on. (Factory default)
Enter 4 45 Seconds. Led 4 on.
Enter 5 60 Seconds. Led 5 on.
Enter 6 90 Seconds. Led 6 on.
ENTER
ENGINEERING
MODE
EXIT
ENGINEERING
MODE
STAY IN
ENGINEERING
MODE
PROGRAMMING
GENERAL
CHIME
SOUND
OPTIONS
TIMERS
EXIT TIME
ENTRY TIME