INSTALLATION
Locate the control panel out of sight, such as in a hall, under stairs or in a
cupboard where connection is easy and the detector zone and mains
cables can be concealed. Avoid areas subject to high temperatures or
humidity such as next to a boiler, airing cupboard or conservatory.
Mounting
1. Remove the lid screws and remove lid.
2. Remove the PCB or keypad packaging.
3. Place the panel in the selected position and mark the three fixing holes.
4. Mount the Panel securely using all three mounting hole positions.
5. Attach the tamper spring and mount the PCB onto the support pillars.
WIRING THE CONTROL PANEL
ELECTRICAL SAFETY NOTICE.
THIS PRODUCT MUST BE EARTHED
This Power Supply must be permanently connected to the mains supply
in accordance with current IEE wiring regulation. A 3 amp fused spur,
installed by a qualified electrician, is strongly recommended.
Any fault which could be mains related must be diagnosed and
corrected by a qualified electrician to ensure continued safe operation.
CAUTION: Under certain circumstances the transformer metalwork
can reach 70°C. this is normal and within prescribed limits.
Battery connection.
Maximum battery size 12V 7.0Ah
This panel requires a standby battery to be fitted to provide power in the
event of mains failure. A valve regulated lead acid battery must be used.
Detector circuits
Connections are provided for up to eight detector circuits of which normally
closed detection devices must be used. A common tamper loop is provided
for all detection devices marked as 24 HR Tamper. One or more devices
may be connected to each alarm circuit. These should be connected in a
series configuration. These circuit connections are located to the bottom
right of the PCB (see diagram B).
PIR Latch Line (L+)
In the event of two or more detectors (motion sensors or glassbreak
detectors) being fitted to any single zone, latching detectors should be
used. The 'L+' connection provides this function. It is low (0 V) when
unset and high (12 V) when set. It should be connected to the appropriate
SET or LATCH terminal in your detector. See glossary for explanation.